Fire risk assessment Types 1–4.

The four types of fire risk assessment classify scope in residential buildings: Type 1 covers common parts non-destructively; Type 2 adds destructive inspection of the common parts; Type 3 extends non-destructively into flats; Type 4 is a destructive whole-building assessment. Type 1 is the benchmark for routine compliance — Types 2 to 4 are escalations triggered by specific doubt about construction or compartmentation.

Updated 9 July 2026 · England & Wales · Regulatory Reform (Fire Safety) Order 2005

The classification, side by side.

The typing system originates in the 2011 guidance Fire Safety in Purpose-Built Blocks of Flats (updated 2022) and is used across the residential sector, by lenders and by insurers. It answers two questions: does the assessment go beyond the common parts, and does it open up construction?

TypeScopeDestructive?Typical trigger
Type 1Common parts onlyNoRoutine statutory compliance — the default for blocks of flats
Type 2Common parts onlyYes — sampled opening-up of constructionReason to suspect defective compartmentation between flats and common parts (e.g. post-refurbishment doubt)
Type 3Common parts + flats (means of escape and detection within dwellings)NoConcern about escape provision or alarm coverage inside flats — common in HMO-style conversions and social housing stock reviews
Type 4Whole buildingYes — in common parts and a sample of flatsSerious doubt about original construction or widespread unauthorised alteration; often follows a fire

What Type 1 must still include

Type 1 is non-destructive but not superficial. Since the Fire Safety Act 2021 it must consider the external wall construction (which may require an EWS1 or FRAEW appraisal under PAS 9980 where cladding risk exists), all flat entrance doors opening onto common parts, and the building's evacuation strategy — stay put or simultaneous evacuation. A Type 1 that ignores external walls is not suitable and sufficient. See assessments in blocks of flats.

Access and cost implications of Types 3 and 4

Types 3 and 4 require access to dwellings, which leaseholders and tenants are not generally obliged to grant without lease provisions or agreement — assessments are usually done on a sample basis. Destructive types also carry making-good costs. This is why competent assessors recommend escalation only against a defined doubt, documented in the Type 1 report, rather than as a default. The cost guide covers typical pricing for each type.

Which type do you actually need?

Key fact: The Types 1–4 system applies to residential buildings. Commercial premises are simply assessed to the Order's standard for the whole workplace — the typing shorthand does not apply, though the destructive/non-destructive distinction is sometimes borrowed.

Common questions.

Is a Type 1 fire risk assessment enough for a block of flats?
In most purpose-built blocks with no evidence of defects, yes — Type 1 is the accepted routine standard. The assessor should state in the report whether anything observed justifies escalation to Type 2, 3 or 4.
Who pays for making good after a Type 2 or Type 4 assessment?
The responsible person commissioning the work — usually the freeholder or management company, recoverable through the service charge where the lease permits. Opening-up and reinstatement should be priced before instruction.
Does a Type 3 assessment let the assessor enter every flat?
No. Access depends on consent or lease rights, so Type 3 and Type 4 assessments are conducted on a representative sample of dwellings, with the sampling rationale recorded.
Is an EWS1 form the same as a Type 4 assessment?
No. EWS1 is a lender-facing external wall appraisal, and a fire risk appraisal of external walls (FRAEW) under PAS 9980 is a technical review of cladding risk. Neither replaces the fire risk assessment; they feed into it.